← Back to product|Datasheet: IO-Link Hub, 16 DI + 16 DO, 8× M12, extension port (BNI IOL-302-002-K006-015) BNI00K9
Product Datasheet
IO-Link Hub, 16 DI + 16 DO, 8× M12, extension port (BNI IOL-302-002-K006-015)
Model: BNI00K9
| Category | IO-Link Masters and Hubs |
| Brand | Balluff |
| Model | BNI00K9 |
| Datasheet PDF | https://r1ju38jd9x.ufs.sh/f/F5LGowJcoU06xrtQHPdgMU0cy2AZsmhEjCx5bqLzGuQI6KSk |
IO-Link hubs - flexible and cost-efficient signal bundling – BNI IOL-302-002-K006-015
Interface: IO-Link 1.1
Operating voltage Ub: 18…30.2 V DC
Connection (COM 1): M12x1-Male, 4-pin, A-coded
Connection slots: 8x M12x1-Female, 5-pin, A-coded
Digital inputs: 16x PNP, Type 3
Digital outputs: 16x PNP
Configurable inputs/outputs: yes
Extension port: yes
Current sum US, sensor: 4 A
Switching current: 16x 350 mA
Current sum UA, actuator: 4 A
Housing material: PA, Transparent, Nickel-plated earthing lug (Sn2..4 µm)
Technical specifications
| General | Model designation | BNI IOL-302-002-K006-015 |
| Electrical | Switching current | 16x 350 mA |
| Electrical | Operating voltage Ub | 18…30.2 V DC |
| Electrical | Current sum US, sensor | 4 A |
| Electrical | Current sum UA, actuator | 4 A |
| Connection | Connection slots | 8x M12x1-Female, 5-pin, A-coded |
| Connection | Connection (COM 1) | M12x1-Male, 4-pin, A-coded |
| Mechanical | Dimension | 50 x 30.8 x 115 mm |
| Mechanical | IP rating | IP67, when threaded in |
| Mechanical | Housing material | PA, Transparent, Nickel-plated earthing lug (Sn2..4 µm) |
| Environment | Ambient temperature | -25…70 °C |
| Communication | Interface | IO-Link 1.1 |
| Communication | Transfer rate | COM2 (38.4 kBaud) |
| Communication | Process data cycle min. | 3.5 ms |
| I/O | Digital inputs | 16x PNP, Type 3 |
| I/O | Extension port | yes |
| I/O | Digital outputs | 16x PNP |
| I/O | Configurable inputs/outputs | yes |