Skip to content
← Back to product|Datasheet: CS AM series safety module, motor standstill detection (CS AM14F1XU-P7) CS AM14F1XU-P7
Product Datasheet

CS AM series safety module, motor standstill detection (CS AM14F1XU-P7)

Model: CS AM14F1XU-P7

InfiSense Technologies
CS AM series safety module, motor standstill detection (CS AM14F1XU-P7)
CategorySafety Relays and Modules
BrandPizzato
ModelCS AM14F1XU-P7
Pizzato Elettrica cS AM series safety module, motor standstill detection, model CS AM14F1XU-P7. Main features: • Function: Module for motor standstill monitoring, up to Cat. 4, SIL 3, PL e • Output contacts: 2 NO safety contacts, 1 NC contact • Communication port: Not programmable • Supply voltage: 24 Vdc • Programme P7: Voltage range 200 mV – 2 V, phase simultaneity time on start-up = 3 s, phase simultaneity time on stop = deactivated, safety output delay on = 1,5 s Approvals (manufacturer data): CE, EAC, TÜV, UKCA, cULus. See the manufacturer catalogue pages (datasheet) for full technical data.

Technical specifications

General | FunctionModule for motor standstill monitoring, up to Cat. 4, SIL 3, PL e
General | ApprovalsCE, EAC, TÜV, UKCA, cULus
General | Programme P7Voltage range 200 mV – 2 V, phase simultaneity time on start-up = 3 s, phase simultaneity time on stop = deactivated, safety output delay on = 1,5 s
General | Supply voltage24 Vdc
General | Output contacts2 NO safety contacts, 1 NC contact
General | Communication portNot programmable

InfiSense Technologies Co., Ltd.