ข้ามไปเนื้อหา
7000-C0101-6340000

ภาพประกอบ สินค้าจริงอาจแตกต่าง

Murrelektronik

สายม้วน (Bulk cable)Cable drum Ø 355mm, PUR 4x0.34 bk UL/CSA+drag ch. 100m

รุ่น7000-C0101-6340000

100m Kabel 10080623(634)auf Spule 01

Number of conductors
4
Conductor cross-section
0.34 mm²
Jacket material
PUR
Jacket color
Black
Cable length
100 m
Weight
5.133 kg
ดูข้อมูลจำเพาะทั้งหมด ↓
LINE

General

Weight
5.133 kg
Country of origin
IT
Model designation
100m Kabel 10080623(634)auf Spule 01

Technical data

Notes
application-related testing
Stranding
1 × 4 wires stranded
Cable Type
3
Amount wires
4
Cable length
100 m
Cable weigth
27.6 g/m
Jacket Color
black / RAL 9005
UL AWM Style
20549 / 10493
Torsion speed
35 cycles/min
Oil resistance
IEC 60811-404
Torsion stress
± 360 °/m
Material jacket
PUR
Flame resistance
UL 1581 § 1090, CSA FT2, IEC 60332-2-2
Wire arrangement
BN, BK, BU, WH
Other resistances
good resistance to gasoline, resistant to hydrolysis, resistant to microbes
Chemical resistance
good
Cable identification
634
Nominal voltage max.
300 V
No. of torsion cycles
5 Mio.
Note on strain relief
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Acceleration (C-track)
10 m/s² @ 25 °C
Bending radius (fixed)
5 × Outer diameter
Travel speed (C-track)
3 m/s @ 25 °C
Material conductor wire
Stranded copper wire, bare
Outer-diameter (jacket)
4.5 mm ± 5 %
Bending radius (dynamic)
10 × Outer diameter
Core construction (wire)
42 × 0.1 mm
Material wire insulation
PP
Outer diameter insulation
1.25 mm ± 0.05 mm
Material property (jacket)
abrasion-resistant, low adhesion, good machinability, matte
Conductor resistance (wire)
57 Ω/km @ 20 °C
Conductor crosssection (wire)
0.34 mm²
Traversing distance (C-track)
10 m @ 25 °C | horizontal
Operating temperature (static)
-40 °C … 80 °C / 90 °C @ 10000 h Operation
No. of bending cycles (C-track)
10 Mio. @ 25 °C
Operating temperature (dynamic)
-25 °C … 80 °C / 90 °C @ 10000 h Operation
Withstand voltage (wire - wire)
2.5 kV @ 60 s
Current load capacity (standard)
to DIN VDE 0298-4
Current load capacity max. (wire)
4.8 A
Freedom from ingredients (jacket)
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
Withstand voltage (wire - jacket)
2.5 kV @ 60 s
Operating temperature (drag chain)
-25 °C … 80 °C / 90 °C @ 10000 h Operation
Ingredient freeness wire insulation
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free

วิธีสั่งซื้อ

  1. 1ส่งคำขอใบเสนอราคาระบุรหัสสินค้าและจำนวนที่ต้องการ
  2. 2รับใบเสนอราคาทีมงานตรวจสอบและส่งใบเสนอราคาให้
  3. 3จัดส่ง / ติดตั้งยืนยันคำสั่งซื้อแล้วจัดส่ง หรือติดตั้งหน้างาน

หาสินค้าไม่เจอ? ส่งรหัสสินค้าให้เราจัดหา

LINE