Skip to content
2467070000

Illustration — the actual product may differ

Weidmüller

Power SuppliesSwitch-mode Power Supply PRO TOP3 120W 24V 5A CO, 24 V DC ± 1 % (2467070000)

Product code2467070000
Output power
120 W
Type
PRO TOP3 120W 24V 5A CO
Series
PROtop
MTBF
According to Standard: SN 29500 Operating time (hours), min.: 2,000,000 h Ambient temperature: 25 °C Input voltage: 400 V Output power: 120 W Duty cycle: 100 % According to Standard: SN 29500 Operating time (hours), min.: 934,000 h Ambient temperature: 40 °C Input voltage: 400 V Output power: 120 W Duty cycle: 100 %
Protection degree
IP20
Degree of efficiency
89%
See all specifications ↓
LINE

General

Type
PRO TOP3 120W 24V 5A CO
Series
PROtop

General data

MTBF
According to Standard: SN 29500 Operating time (hours), min.: 2,000,000 h Ambient temperature: 25 °C Input voltage: 400 V Output power: 120 W Duty cycle: 100 % According to Standard: SN 29500 Operating time (hours), min.: 934,000 h Ambient temperature: 40 °C Input voltage: 400 V Output power: 120 W Duty cycle: 100 %
Protection degree
IP20
Degree of efficiency
89%
Short-circuit protection
Yes internal
Mounting position, installation notice
Horizontal on DIN rail TS 35, top and bottom 50 mm clearance for free air flow, 10 mm clearance to neighbouring subassemblies.

Electrical safety (applied standards)

Safety extra-low voltage
SELV acc. to IEC 60950-1 PELV according to EN 60204-1

Output

Output power
120 W
Connection system
PUSH IN with actuator
Output voltage, max.
28.8 V
Output voltage, min.
22.5 V
Output voltage, note
adjustable with potentiometer or comunication module
Rated output voltage
24 V DC ± 1 %
Parallel connection option
Yes, for redundancy and power increase (with ORing MOSFET)
Residual ripple, breaking spikes
< 50 mVss @ UNenn, Full Load

Connection data (input)

Connection system
PUSH IN with actuator
Number of terminals
4 for L1/L2/L3/PE
Conductor cross-section, rigid , max.
1.5 mm²
Conductor cross-section, rigid , min.
0.5 mm²
Conductor cross-section, flexible , min.
0.5 mm²
Conductor cross-section input (AWG), max.
12 AWG
Conductor cross-section (AWG) (input), min.
20 AWG

Connection data (output)

Connection system
PUSH IN with actuator
Conductor cross-section, rigid , max.
2.5 mm²
Conductor cross-section, rigid , min.
0.2 mm²
Conductor cross-section, flexible , max.
2.5 mm²
Conductor cross-section (AWG) (output), max.
12 AWG
Conductor cross-section (AWG) (output) , min.
26 AWG

Dimensions and weights

Depth
125 mm
Width
39 mm
Height
130 mm
Net weight
967 g

EMC / shock / vibration

Shock resistance IEC 60068-2-27
30 g in all directions
Interference immunity test acc. to
EN 55032 (EN 55022) EN 61000-6-1, 2, 3, 4
Vibration resistance IEC 60068-2-6
2.3 g (on DIN rail) 4 g (with direct mounting)

Input

Inrush current
Max. 10 A
Connection system
PUSH IN with actuator
Frequency range AC
45…65 Hz
Rated input voltage
3x 400...3x 500 V AC (wide-range input)
AC input voltage range
3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC
Recommended back-up fuse
1 - 2 A, Char. C
Power consumption, nominal
134.8 VA
Current consumption in relation to the input voltage
Voltage type: 3-phase AC Input voltage: 320 V Input current: 1 A Voltage type: DC Input voltage: 400 V Input current: 0.4 A

Insulation coordination

Insulation voltage (input / earth)
3.2 kV
Insulation voltage (input / output)
3.5 kV
Insulation voltage (output / earth)
0.5 kV

Temperatures

Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...70 °C

How to order

  1. 1Send a quote requestList the product codes and quantities you need
  2. 2Receive the quotationOur team checks the request and sends you a quotation
  3. 3Delivery / installationConfirm the order, then we deliver or install on site

Can't find a product? Send us the product code and we'll source it

LINE